离子色谱电感耦合等离子体质谱联用法测定水中痕量BrO_3~-及Br~-

dc.contributor.author沈金灿
dc.contributor.author荆淼
dc.contributor.author陈登云
dc.contributor.author沈阳
dc.contributor.author王小如
dc.contributor.authorFrank S. C. Lee
dc.date.accessioned2017-11-14T01:49:00Z
dc.date.available2017-11-14T01:49:00Z
dc.date.issued2005-07-25
dc.description.abstract建立了离子色谱电感耦合等离子体质谱联用技术(ICICPMS)用于饮用水中的痕量BrO-3及Br-的测量。使用DIONEXCarbopacPA100(4mm×250mmi.d.)在流速1mL/min及5mmol/LNH4NO3(pH5.7)淋洗液下进行BrO-3和Br-的分离。该方法以100μL进样量对BrO-3的检出限为0.0027μmol/L(0.22μg/L);对Br-的检出限为0.0067μmol/L(0.54μg/L)。对水样的分析结果表明,所测矿泉水中的BrO-3浓度大大超出了世界卫生组织最新《饮用水水质准则》中所规定的溴酸盐的指导值,而所测量的青岛崂山区生活用水则未检出BrO-3。
dc.description.abstractWith the widely application of disinfection of drinking water utilizing ozone, the impact of bromide formed in the ozonization process on people′s health was paid more attention. In this paper a method to determine trace BrO -_3 and Br - in water by ion chromatography coupled with inductively coupled plasma mass spectrometric detection was developed. BrO -_3 and Br - were separated on a DIONEX Carbopac PA-100(4 mm×250 mm i.d.)column with 5 mmol/L NH_4NO_3 (pH 5.7) eluent solution at 1 mL/min. The detection limit for BrO -_3 was 0.0027 μmol/L, and 0.0067 μmol/L for Br -. The results show that the concentration of BrO -_3 in mineral water analyzed by the method developed in the present work is much higher than that proposed by the World Healty Organization, while no BrO -_3 was detected in drinking water in Laoshan area of Qingdao. [JP2]
dc.identifier.citation分析化学,2005,(07):100-102
dc.identifier.issn0253-3820
dc.identifier.otherFXHX200507023
dc.identifier.urihttps://dspace.xmu.edu.cn/handle/2288/143686
dc.language.isozh_CN
dc.subject
dc.subject溴酸盐
dc.subject离子色谱
dc.subject电感耦合等离子体质谱
dc.subject
dc.subjectBromine, bromate, ion chromatography, inductively coupled plasma mass spectrometry, water
dc.title离子色谱电感耦合等离子体质谱联用法测定水中痕量BrO_3~-及Br~-
dc.title.alternativeDetermination of Trace BrO_3~- and Br_- in Drinking Water by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry
dc.typeArticle